Wednesday, 4 July 2012

ELECTRICAL SYMBOLS AND REFERENCE DESIGNATIONS





The symbols presently used to designate electrical/ electronic parts and assemblies in NAVSEA drawings are specified in ANSI Y32.2-1975, Graphic Symbols for Electrical and Electronics Diagrams. This publication provides alternate methods for symbolizing certain parts and should be consulted when a symbol is not clearly understood. The electrical/electronic schematic print section of your systems maintenance manual will normally provide a description of the symbols used. Figure 5-15 shows the electrical symbols used in the reference drawings of gun mounts currently in service.
In some modem gun mounts and GMLSs, other than standard reference designations may be used for parts peculiar to a particular system. In this event, the manufacturer assigns reference designation letters and numbers. Normally, the designations used by each manufacturer are published in the OP for that particular gun mount.
In general, the electrical components or devices used in a modem gun mount or GMLS (the 5"/54 Mk 45 or Mk 13 Mod 4) are identified by a combination of letters and numbers or groups of letters and numbers. Table 5-1 is a partial listing of first- and second-group designation used on the Mk 45 gun mount. The first two letters identify a specific type of component. The third letter identifies the major equipment assembly within which the component is located. The number that follows the third letter indicates the number of the
Table 5-1.-Electrical Component Designations
Figure 5-15.-Electrical symbols.
device within the assembly. For example, SIH1 is an interlock switch (SI) used in the left upper hoist(H) and the number 1 distinguishes this particular switch from all other switches in the hoist.
As is often the case, there is one modem gun mount (76-mm 62-caliber Mk 75) in which both the electrical symbols and designations are not all consistent with other gun mounts. For example, a relay is designated with a number followed by the letter K, followed by another number (1K1, 2K1, and soon). The symbol for a relay is a rectangular box.

IDENTIFICATION OF CONDUCTORS 


A conductor used as a grounded conductor shall be identifiable and distinguishable from all other conductors. A conductor used as an equipment grounding conductor shall be identifiable and distinguishable from all other conductors.

The grounded conductor is an energized circuit conductor that is connected to earth through the system ground. It is commonly referred to as the neutral. The equipment grounding conductor is not an energized conductor under normal conditions. The equipment grounding conductor acts as a safeguard against insulation failure or faults in the other circuit conductors. The equipment grounding conductor is energized only if there is a leak or fault in the normal current path, and it directs this current back to the source. Directing the fault current back to the source enables protective devices, such as circuit breakers or fuses, to operate thus preventing fires and reducing the hazard of electrical shocks.

The grounded and equipment grounding conductors of an electrical circuit must be marked or color coded in a way that allows employees to identify them and tell them apart from each other and from the other conductors in the circuit.

The figure below illustrates a distribution panelboard. One means by which each conductor's use is identified and made distinguishable from the other circuit conductors is the use of color coding. Acceptable color coding includes the method required by the National Electrical Code, Section 210-5. The Code states: "The grounded conductor of a branch circuit shall be identified by a continuous white or natural gray color." Also, "The equipment grounding conductor of a branch circuit shall be identified by a continuous green color or a continuous green color with one or more yellow stripes unless it is bare." Bare copper or aluminum wire is permitted for use as a grounding conductor.


image

POLARITY OF CONNECTIONS

No grounded conductor may be attached to any terminal or lead so as to reverse designated polarity.

A grounding terminal or grounding-type device on a receptacle, cord connector, or attachment plug may not be used for purposes other than grounding.

The above two subparagraphs dealing with polarity of connections and use of grounding terminals and devices address one potentially dangerous aspect of alternating current: many pieces of equipment will operate properly even though the supply wires are not connected in the order designated by design or the manufacturer. Improper connection of these conductors is most prevalent on the smaller branch circuit typically associated with standard 120 volt receptacle outlets, lighting fixtures and cord- and plug-connected equipment.

When plugs, receptacles, and connectors are used in an electrical branch circuit, correct polarity between the ungrounded (hot) conductor, the grounded (neutral) conductor, and the grounding conductor must be maintained.

Reversed polarity is a condition when the identified circuit conductor (the grounded conductor or neutral) is incorrectly connected to the ungrounded or "hot" terminal of a plug, receptacle, or other type of connector.

The figure below shows the correct wiring for the common 120-volt outlet with a portable hand tool attached.

typical 120 volt branch circuit with correct wiring

Suppose now that the black (ungrounded) and white (grounded) conductors are reversed as shown in the figure below. This is the traditional reversed polarity. Although a shock hazard may not exist, there are other mechanical hazards that can occur.


120 volt branch circuit with black and white wires reversed

For example, if an internal fault should occur in the wiring as shown in the figure below, the equipment would not stop when the switch is released or would start as soon as a person plugs the supply cord into the improperly wired outlet. This could result in serious injury.

120 volt branch circuit with black and white wires reversed internal fault in equipment wiring

The figure below shows the white (grounded) and green (grounding) conductors reversed. Although it is not fitting, considering OSHA or code terminology, to call this reversed polarity, a hazard can still exist. In this case, due to the wiring error, the white wire is being used to provide equipment grounding. Under certain conditions, this could be dangerous.


white and green wires reversed

The figure below shows an extremely dangerous situation. In this example, the black (ungrounded) and green (grounding) conductors have been reversed. The metal case of the equipment is at 120 volts with reference to the surroundings. As soon as a person picks up the equipment and touches a conductive surface in their surrounding, they will receive a serious, or even deadly, shock.

Although the equipment will not work with this wiring error, it would not be unusual for a person to pick up the equipment before realizing this. The person may even attempt to troubleshoot the problem before unplugging the power cord.


black and green wires reversed

Correct polarity is achieved when the grounded conductor is connected to the corresponding grounded terminal and the ungrounded conductor is connected to the corresponding ungrounded terminal. The reverse of the designated polarity is prohibited. The figure below illustrates a duplex receptacle correctly wired. Terminals are designated and identified to avoid confusion. An easy way to remember the correct polarity is "white to light" - the white (grounded) wire should be connected to the light or nickel-colored terminal; "black to brass" - the black or multi-colored (ungrounded) wire should be connected to the brass terminal; and "green to green" - the green or bare (grounding) wire should be connected to the green hexagonal head terminal screw.

duplex receptacle correctly wired to designated terminals

GROUNDING

This section contains grounding requirements for systems, circuits, and equipment. Grounding electrical circuits and electrical equipment is required to protect employees against electrical shock, safeguard against fire, and protect against damage to electrical equipment. There are two kinds of grounding: (1) electrical circuit or system grounding, and (2) electrical equipment grounding. Electrical system grounding is accomplished when one conductor of the circuit is intentionally connected to earth. This is done to protect the circuit should lightning strike or other high voltage contact occur. Grounding a system also stabilizes the voltage in the system so "expected voltage levels" are not exceeded under normal conditions. The second kind of ground is equipment grounding. This is accomplished when all metal frames of equipment and enclosures containing electrical equipment or conductors are grounded by means of a permanent and continuous connection or bond. The equipment grounding conductor provides a path for dangerous fault current to return to the system ground at the supply source of the circuit should an insulation failure take place. If installed properly, the equipment grounding conductor is the current path that enables protective devices, such as circuit breakers and fuses, to operate when a fault occurs. The figure below illustrates both types of grounding.

system and equipment grounding

GROUNDING PATH

The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

This requirement was extracted from NEC 250-51, Effective Grounding Path, which is more complete and fundamental to the understanding of electrical safety. It states that the path to ground:

  1. "shall be permanent and continuous." (If the path is installed in such a way that damage, corrosion, loosening, etc. may impair the continuity during the life of the installation, then shock and burn hazards will develop.)
     

  2. "shall have capacity to conduct safely any fault current likely to be imposed on it." (Fault currents may be many times normal currents, and such high currents may melt or burn metal at points of poor conductivity. These high temperatures may be a hazard in themselves, and they may destroy the continuity of the ground-fault path.)
     

  3. "shall have sufficiently low impedance to limit the voltage to ground and to facilitate the operation of the circuit protective devices in the circuit." (If the ground-fault path has a high impedance, there will be hazardous voltages whenever fault currents attempt to flow. Also, if the impedance is high, the fault current will be limited to some value so low that the fuse or circuit breaker will not operate promptly, if at all.)

It is important to remember the following regarding safe grounding paths:

  1. The fault current in A-C circuits will be limited by the sum of resistance and reactance, and the only low-reactance path is that which closely follows the circuit conductors.
     

  2. If a metallic raceway system is used, make sure that the metallic system is continuous and permanent.
     

  3. In cases where a metallic raceway system is not used, provide a green or bare equipment-grounding conductor close to the supply conductors to assure that all enclosures are bonded together and to the source.

GROUNDING OF EQUIPMENT CONNECTED BY CORD AND PLUG

Under any of the conditions described below, exposed non-current-carrying metal parts of cord- and plug-connected equipment which may become energized shall be grounded.


a. If in a hazardous (classified) location.


b. If operated at over 150 volts to ground, except for guarded motors and metal frames of electrically heated appliances if the appliance frames are permanently and effectively insulated from ground.


c. If the equipment is of the following types:


Refrigerators, freezers, and air conditioners;
 


Clothes-washing, clothes-drying and dishwashing machines, sump pumps, and electrical aquarium equipment;
 


Hand-held motor-operated tools;
 


Motor-operated appliances of the following types: hedge clippers, lawn mowers, snow blowers, and wet scrubbers;
 


Cord- and plug-connected appliances used in damp or wet locations or by employees standing on the ground or on metal floors or working inside of metal tanks or boilers;
 


Portable and mobile X-ray and associated equipment;
 


Tools likely to be used in wet and conductive locations; and
 


Portable hand lamps.

Under the conditions described above, exposed non-current-carrying metal parts of cord- and plug-connected equipment must be grounded. Grounding metal parts is not required where the equipment is supplied through an isolating transformer with an ungrounded secondary of not over 50 volts or if portable tools are protected by an approved system of double insulation. To ground cord- and plug-connected equipment, a third wire is commonly provided in the cord set and a third prong in the plug. The third wire serves as an equipment grounding conductor which is connected to the metal housing of a portable tool and a metal grounding bus inside the service entrance equipment. The service entrance equipment is located at the entrance point of the electric supply for a building or plant and contains, or serves other panelboards which contain, branch circuit protective devices such as fuses and circuit breakers. The third wire provides a path for fault current should an insulation failure occur. In this manner, dangerous fault current will be directed back to the source, the service entrance, and will enable circuit breakers or fuses to operate, thus opening the circuit and stopping the current flow.

The figure below illustrates the potential shock hazard that exists when no third wire, grounding conductor, is used. If a fault occurs, most of the current will follow the path of least resistance. If the worker provides a path to ground as shown, some portion of the current will flow away from the grounded white conductor (neutral) and return to ground through the worker. The severity of the shock received will depend on the amount of current that flows through the worker.

cord- and plug-connected equipment without a grounding conductor

The figure below illustrates the advantage of a properly connected grounded conductor. It should be noted that properly bonded conduit and associated metal enclosures can also serve as a grounding conductor.

cord- and plug-connected equipment with a grounding conductor

Tools likely to be used in wet and conductive locations need not be grounded if supplied through an isolating transformer with an ungrounded secondary of not over 50 volts. Listed or labeled portable tools and appliances protected by an approved system of double insulation, or its equivalent, need not be grounded. If such a system is employed, the equipment shall be distinctively marked to indicate that the tool or appliance utilizes an approved system of double insulation.

GROUND-FAULT CIRCUIT-INTERRUPTERS

Introduction

imageIn most cases, insulation and grounding are used to prevent injury from electrical wiring systems or equipment. However, there are instances when these recognized methods do not provide the degree of protection required. To help appreciate this, let's consider a few examples of where ground fault circuit interrupters would provide additional protection.


Many portable hand tools, such as electric drills, are now manufactured with non-metallic cases. If approved, we refer to such tools as double insulated. Although this design method assists in reducing the risk from grounding deficiencies, a shock hazard can still exist. In many cases, persons must use such electrical equipment where there is considerable moisture or wetness. Although the person isinsulated from the electrical wiring and components, there is still the possibility that water can enter the tool housing. Ordinary water is a conductor of electricity. Therefore, if the water contacts energized parts, a path will be provided from inside the housing to the outside, bypassing the double insulation. When a person holding a hand tool under these conditions touches another conductive surface in their work environment, an electric shock will result.
 


Double-insulated equipment or equipment with non-metallic housings, that does not require grounding under the National Electrical Code, is frequently used around sinks or in situations where the equipment could be dropped into water. Frequently, the initial human response is to grab for the equipment. If a person's hand is placed in the water and another portion of their body is in contact with a conductive surface, a serious or deadly electric shock can occur.
 


In construction work and regular factory maintenance work, it is frequently necessary to use extension cord sets with portable equipment. These cords are regularly exposed to physical damage. Although safe work procedures require adequate protection, it is not possible to prevent all damage. Frequently, the damage is only to the insulation, exposing energized conductors. It is not unusual for a person to handle the cord often with the possibility of contacting the exposed wires while holding a metal case tool or while in contact with other conductive surfaces.
The amount of current which flows under such conditions will be enough to cause serious human response. This can result in falls or other physical injury and in many cases death.

Since neither insulation (double insulation) nor grounding can provide protection under these conditions, it is necessary to use other protective measures. One acceptable method is a ground fault circuit interrupter, commonly referred to as a GFCI.

How Ground-Fault Circuit-Interrupters Work

A ground-fault circuit-interrupter is not an overcurrent device like a fuse or circuit breaker. GFCI's are designed to sense an imbalance in current flow over the normal path.

The GFCI contains a special sensor that monitors the strength of the magnetic field around each wire in the circuit when current is flowing. The magnetic field around a wire is directly proportional to the amount of current flow, thus the circuitry can accurately translate the magnetic information into current flow.

If the current flowing in the black (ungrounded) wire is within 5 (plus or minus 1) milliamperes (mA) of the current flowing in the white (grounded) wire at any given instant, the circuitry considers the situation normal. All the current is flowing in the normal path. If, however, the current flow in the two wires differs by more than 5 mA, the GFCI will quickly open the circuit. This is illustrated in the figure below.

how the GFCI protects people

Note that the GFCI will open the circuit if 5 mA or more of current returns to the service entrance by any path other than the intended white (grounded) conductor. If the equipment grounding conductor is properly installed and maintained, this will happen as soon as the faulty tool is plugged in. If by chance this grounding conductor is not intact and of low-impedance, the GFCI may not trip out until a person provides a path. In this case, the person will receive a shock, but the GFCI should trip out so quickly that the shock will not be harmful.

Types of Ground-Fault Circuit-Interrupters

There are several types of GFCI's available, with some variations to each type. Although all types will provide ground-fault protection, the specific application may dictate one type over another.


Circuit-Breaker Type
The circuit-breaker type includes the functions of a standard circuit breaker with the additional functions of a GFCI. It is installed in a panelboard and can protect an entire branch circuit with multiple outlets. It is a direct replacement for a standard circuit breaker of the same rating.
 


Receptacle Type
The receptacle style GFCI incorporates within one device one or more receptacle outlets, protected by the GFCI. Such devices are becoming very popular because of their low cost. Most are of the duplex receptacle configuration and can provide GFCI protection for additional non-GFCI type receptacles connected "down stream" from the GFCI unit.
 


Permanently Mounted Type
The permanently mounted types are mounted in an enclosure and designed to be permanently wired to the supply. Frequently they are used around large commercial swimming pools or similar wet locations.
 


Portable Type
Several styles of portable GFCI's are available. The portable types are designed to be easily transported from one location to another. They usually contain one or more integral receptacle outlets protected by the GFCI module. Some models are designed to plug into existing non-GFCI protected outlets, or in some cases, are connected with a cord and plug arrangement. The portable type also incorporate a no-voltage release device which will disconnect power to the outlets if any supply conductor is open. Units approved for use outdoors will be in enclosures suitable for the environment. If exposed to rain, they must be listed as rainproof.
 


Cord Connected Type
The power supply cord type GFCI consists of an attachment plug which incorporates the GFCI module. It provides protection for the cord and any equipment attached to the cord. The attachment plug has a non-standard appearance and is equipped with test and reset buttons. Like the portable type, it incorporates a no-voltage release device which will disconnect power to the load if any supply conductor is open.

Classes of Ground-Fault Circuit-Interrupters

Ground-Fault Circuit-Interrupters are divided into two classes: Class A and Class B. The Class A device is designed to trip when current flow, in other than the normal path, is 6 milliamperes or greater. The specification is 5 milliamperes ± 1 milliampere. The Class B device will trip when current flow, in other than the normal path, is 20 milliamperes or greater. Class B devices are approved for use on underwater swimming pool lighting installed prior to the adoption of the 1965 National Electrical Code.

Testing Ground-Fault Circuit-Interrupters

Due to the complexity of a GFCI, it is necessary to test the device on a regular basis. For permanently wired devices, a monthly test is recommended. Portable type GFCI's should be tested each time before use. GFCI's have a built-in test circuit which imposes an artificial ground fault on the load circuit to assure that the ground-fault protection is still functioning. Test and reset buttons are provided for testing.

CABINETS, BOXES, AND FITTINGS

Conductors Entering Boxes, Cabinets, or Fittings

Since conductors can be damaged if they rub against the sharp edges of cabinets, boxes, or fittings, they must be protected from damage where they enter. To protect the conductors, some type of clamp or rubber grommet must be used. The device used must close the hole through which the conductor passes as well as provide protection from abrasion. If the conductor is in a conduit and the conduit fits tightly in the opening, additional sealing is not required.

The knockouts in cabinets, boxes, and fittings should be removed only if conductors are to be run through them. However, if a knockout is missing or if there is another hole in the box, the hole or opening must be closed.

Covers and Canopies

All pull boxes, junction boxes, and fittings shall be provided with covers approved for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

FLEXIBLE CORDS AND CABLES

This standard for safe use of flexible cords is one of the most frequently violated electrical standards, particularly in smaller plants. There is a definite need and place for cords, but there is also a temptation to misuse them because they seem to offer a quick and easy way to carry electricity to where it is needed. The basic problem is that flexible cords in general are more vulnerable than the fixed wiring of the building. Therefore, cords should not be used if one of the recognized wiring methods could be used instead.

Use of Flexible Cords and Cables

Flexible cords and cables shall be approved and suitable for conditions of use and location. The standard lists specific situations in which flexible cords may be used. Flexible cords and cables shall be used only for:

a. Pendants (a lampholder or cord-connector body suspended by a length of cord properly secured and terminated directly above the suspended device);

b. Wiring of fixtures;

c. Connection of portable lamps or appliances;

d. Elevator cables;

e. Wiring of cranes and hoists (where flexibility is necessary);

f. Connection of stationary equipment to facilitate their frequent interchange (equipment which is not normally moved from place to place, but might be on occasion);

g. Prevention of the transmission of noise or vibration. (In some cases vibration might fatigue fixed wiring and result in a situation more hazardous than flexible cord.)

h. Appliances where the fastening means and mechanical connections are designed to permit removal for maintenance and repair (e.g. water coolers, exhaust fans);

i. Data processing cables approved as a part of the data processing system.

Note that all of the above situations involve conditions where flexibility is necessary. Unless specifically permitted by one of these situations, flexible cords and cables may not be used:

a. As a substitute for the fixed wiring of the structure;

b. Where run through holes in walls, ceilings, or floors;

c. Where run through doorways, windows, or similar openings;

d. Where attached to building surfaces; or

e. Where concealed behind building walls, ceilings, or floors.

There is usually not much question about use of the short length of cord which is furnished as part of an approved appliance or tool; there is usually no question about an extension cord used temporarily to permit use of the appliance or tool in its intended manner at some distance from a fixed outlet; but there are questions when the usage is not obviously temporary, and when the cord is extended to some distant outlet in order to avoid providing a fixed outlet where needed.

Flexible cord used in violation of this standard is likely to be damaged by activities in the area; by door or window edges; by staples or fastenings; by abrasion from adjacent materials; or simply by aging. If the conductors become partially exposed over a period of time, there will be danger of shocks, burns, or fire.

Identification, Splices and Terminations

Flexible cords shall be used only in continuous lengths without splice or tap. Hard service flexible cords, No. 12 or larger, may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.

Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.
Discussion - 1.9 MB 

Overhead - 1.83 MB 

Student Handouts - 668 K 

Self-Inspection Checklist


INTRODUCTION


Electricity has become an essential of modern life, both at home and on the job. Some employees work with electricity directly, as is the case with engineers, electricians, or people who do wiring, such as overhead lines, cable harnesses, or circuit assemblies. Others, such as office workers and salespeople, work with it indirectly. As a source of power, electricity is accepted without much thought to the hazards encountered. Perhaps because it has become such a familiar part of our surroundings, it often is not treated with the respect it deserves.
OSHA's electrical standards address the government's concern that electricity has long been recognized as a serious workplace hazard, exposing employees to such dangers as electric shock, electrocution, fires and explosions. The objective of the standards is to minimize such potential hazards by specifying design characteristics of safety in use of electrical equipment and systems.
OSHA's electrical standards were carefully developed to cover only those parts of any electrical system that an employee would normally use or contact. The exposed and/or operating elements of an electrical installation - lighting equipment, motors, machines, appliances, switches, controls, enclosures, etc. - must be so constructed and installed as to minimize electrical dangers to people in any workplace.
The OSHA electrical standards were based on the National Fire Protection Association's standard NFPA 70E, Electrical Safety Requirements for Employee Workplaces, and the NFPA 70 Committee derived Part I of their document from the 1978 edition of the National Electrical Code (NEC). The standards extracted from the NEC were those considered to most directly apply to employee safety and least likely to change with each new edition of the NEC. OSHA's electrical standards are performance oriented; therefore they contain few direct references to the NEC. However, the NEC contains specific information as to how the required performance can be obtained.
This discussion does not cover OSHA's Electrical Safety-Related Work Practices Standard, which contains requirements for working on or near energized and de-energized electrical equipment, the use of personal protective equipment, and the safe use of electrical equipment.
This discussion covers requirements in OSHA's Design Safety Standards for Electrical Systems that are frequently overlooked and may present serious hazards. The reader is encouraged to consult the complete text of O
SHA's electrical standards for all of OSHA's requirements.

Electrical Safety Information





Avoid Hazards
Electricity is essential to modern life. Because it's used every day, it often isn't treated with the respect it deserves. Some 350 electrical-related fatalities occur each year.  The following hazards are the most frequent causes of electrical injuries:
Contact with Power Lines
Overhead and buried power lines are especially hazardous because they carry extremely high voltage. Fatal electrocution is the main risk, but burns and falls from elevations are also hazards. Using tools and equipment that can contact power lines increases the risk. Examples of equipment that can contact power lines include:
  • Aluminum paint rollers
  • Backhoes
  • Concrete pumper
  • Cranes
  • Long-handled cement finishing floats
  • Metal building materials
  • Metal ladders
  • Raised dump truck beds
  • Scaffolds
  • Irrigation Pipe
To avoid hazards:
  • Look for overhead power lines and buried power line indicators.
  • Post warning signs.
  • Contact utilities for buried power line locations.
  • Stay at least 10 feet away from overhead power lines.
  • Unless you know otherwise, assume that overhead lines are energized.
  • Use non-conductive wood or fiberglass ladders when working near power lines.
Lack of Ground Fault Protection
Normal use of electrical equipment can cause wear and tear that results in insulation breaks, short-circuits, and exposed wires. Without proper protection, a ground fault can occur, resulting in electrical burns, explosions, fire or death.
To avoid ground fault hazards:
  • Use ground-fault circuit interrupters on all 120-volt, single-phase, 15- and 20-ampere receptacles, or have an assured equipment grounding conductor program.
  • Follow manufacturers' recommended testing procedure to insure GFCI is working correctly.
  • Use double-insulated tools and equipment, distinctively marked.
  • Use tools and equipment according to the instructions included in their listing, labeling or certification.
  • Visually inspect all electrical equipment before use. Remove from service any equipment with frayed cords, missing ground prongs, cracked tool casings, etc.
Strain Relief
Flexible cords are finely stranded for flexibility, so straining a cord can cause the strands of one conductor to loosen from under terminal screws and touch another conductor. Make sure flexible cords are connected to devices and to fittings in ways that prevent tension at joints and terminal screws.
Cord Damage
A flexible cord may be damaged by door or window edges, by staples and fastenings, by abrasion from adjacent materials or simply by aging. If the electrical conductors become exposed, there is a danger of shocks, burns, or fire.
Grounding
Extension cords must be 3-wire type so they may be grounded and to permit grounding of any tools or equipment connected to them.
Wet Conditions
When a cord connector is wet, electric current can leak to the equipment grounding conductor and to humans who pick up that connector if they provide a path to ground. Leakage can occur not just on the face of the connector, but at any wetted portion. Limit exposure of connectors and tools to excessive moisture by using watertight or sealable connectors.
  • Stay away from downed power lines, you never know if one is "live"
  • Always fly your kites and model planes in open fields, away from overhead power lines or electrical equipment.
  • Keep things that use electricity away from sinks and bathtubs.
  • Never use an appliance while standing in water or on a wet floor.
  • Don't stick anything in an outlet other than a plug or plastic cap.
  • Avoid shocks by pulling the plug, not the cord (wires won't break inside either.)
  • Don't let cords dangle where you may trip over them.
Pad Mount Transformers
What are those green electrical boxes found in yards or back alleys? To the Electric Utility these boxes are known as Pad mount Transformers. Pad mount transformers lower the voltage of the electricity from distribution levels to the 120/240-volt level used in homes. They are located in the Utility-Right-of-Way in underground services areas. If you have one on your property, contact Umatilla Electric Cooperative about landscaping and fencing around transformers. You can reach us at 567-6414. While the transformers are safe on the property, follow the safety signs on the transformer and keep curious children away.
Safety Tips When You Fly a Kite!
  • DO fly kites in clear sunny weather, not storms.
  • DO make your kite from paper, wood, plastic, nylon or fabric, making sure there are no metal parts on your kite.
  • DO NOT climb a power pole or tree to get a kite tangled in overhead power lines.
  • DO call Umatilla Electric Cooperative to take down a kite that is touching a power line.
  • DO check wind direction before flying your kite to avoid hazards; keep control of your kite by using a reasonable length of string.
  • DO have fun flying your kite safely!
Electrical Storms
The lazy, hazy, hot days of summer provide the right atmosphere for sudden thunder and lightning storms. Lightning is a form of static electricity and like other forms of electricity, lightning looks for a path to the ground. It will use the best conductor available, including water, a tree, a kite string, or a person.
Electricity always tries to get to the ground. It follows the shortest and easiest path it can. Metal materials such as copper and aluminum, things that are wet and anything with water in it, including people and wood, are good conductors of electricity. Tree sap, with its high water content, is an excellent conductor of electricity.
Listed are some safe practices to ensure your safety during electrical storms:
  • stay indoors
  • stay away from open doors and windows, metal pipes, sinks and plug-in electrical appliances
  • do not take laundry off the clothesline
  • do not work on fences, telephone lines, power lines, pipelines or metal buildings
  • do not use metal objects, such as fishing rods and golf clubs. Golfers wearing metal cleated shoes are particularly good lightning rods
  • stop tractor work, especially when the tractor is pulling metal equipment and get off the tractor
  • get out of the water and off small boats
  • stay in the car if you are traveling. Automobiles offer excellent lightning protection
  • when there is no shelter, avoid the highest object in the area. If only isolated trees are nearby, the best protection is to crouch in the open, keeping twice as far away from isolated trees as the trees are high
  • avoid hilltops, open spaces, wire fences, metal clotheslines, and any high objects which may conduct electricity                  for more information click here